摘要
采用冷态对比实验研究从灰斗引出排气管的新型顺流式旋风分离器的分离性能。试验考察了导流体直径、导流体长度、导流体-排气管口距离、排气口直径等结构因素对分离性能的影响以及不同入口气速条件下的分离性能。研究结果为该类型旋风分离器的优化设计提供了依据。
The separation efficiency and pressure drop of a new type of cyclone separator with a downward exhaust gas pipe from dust hopper were experimentally investigated with different constructional parameters and under different operation conditions. Results showed that there were optimal values of inducer diameter, length, and inducer-exhaust distance for best separation efficiency. The results in this study is valuable for the design and optimization of the cyclone separators with similar styles.
出处
《过滤与分离》
CAS
2006年第2期16-18,41,共4页
Journal of Filtration & Separation
关键词
旋风分离器
下排气
分离效率
cyclone separator
downward exhaust gas
separation efficiency