对洁净空调系统原设计施工图和相关设备的技术参数进行调整优化,并严把施工质量关,保证了10000级洁净实验生产间要求的空调技术参数,达到了预期的建设目的。该洁净空调系统投入使用四年多以来,效果很好,为激光导航仪器的生产提供了优良的实验与生产环境。
The original designing documents and technique parameter of equipment of cleaning air condition are adjusted and optimized. The quality of construction is paid more attention in the actual construction, and the expected aim is achieved. Therefore, this system's effect is good for using more than four years, which ensures the environment quality for laser navigation device production.