针对隆源公司C40—4.12/0.998型机组热电改造后由于调速系统晃动而不能正常运行的现象,从调速系统调节原理、设备构造方面分析了引起调速系统晃动的原因,并提出处理方法。
After reconstruction the Longyuan unit 8 turbine could not work regularly because of the rock of the governing system. In this article the possible reasons causing the vibration are analyzed according to the principle and structure of the system and feasible solutions are also proposed.
出处
《安徽电力》
2006年第2期26-28,78,共4页
Anhui Electric Power
关键词
调速系统
晃动
分析
speed adjustment system
vibration
analyses