水-水中高温热泵系统的优化设计 被引量:2

Optimal Design of Water to Water Moderate and High Temperature Heat Pump System
下载PDF
导出
摘要 本文以节能节材为目的,对水-水中高温热泵系统进行了优化设计,以经济参数F为目标函数对系统进行经济性评价。本文将水泵功率考虑在内,并研究了过热度,过冷度,两器水流量以及两器的面积分配对F的影响,旨在更全面的评价水-水热泵性能,实现系统各部件的最佳匹配。 Optimal design is done for water to water moderate and high temperature heat pump system from the viewpoint of saving energy and materials. A parameter F is defined as the objective function to make economic evaluation for the system. In this paper, work cost of water pump is taken into consideration, and some other factors influencing F are analyzed, which include superheat, subcooling, water flux of the heat exchanger and the distribution of the heat - transfer area of the heat exchanger. The aim of this study is to get a better understanding of the performance of water to water heat pump and to obtain the optimal, matching of various components of the system.
出处 《节能技术》 CAS 2006年第3期227-230,共4页 Energy Conservation Technology
关键词 中高温热泵 优化设计 经济性评价 moderate and high temperature heat pump optimal design economic evaluation
  • 相关文献

参考文献4

  • 1马利敏,王怀信,郑臣明,杨强,张宇.几种中高温热泵混合工质的研究[C].中国工程热物理学会工程热力学与能源利用学术会议论文集,上海,2003:572-577. 被引量:1
  • 2张宇,王怀信,马利敏.一种中高温热泵混合工质的实验研究[J].工程热物理学报,2005,26(6):924-926. 被引量:9
  • 3M.M.Salah El-Din.Optimization of totally irreversible refrigerators and heat pumps[J].Energy Conversion & Management,1999,40:423-436. 被引量:1
  • 4Ali Kodal,Bahri Sahin,Tamer Yilmaz.Effects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps[J].Energy Conversion &Management,2000,41:607-619. 被引量:1

二级参考文献4

共引文献8

同被引文献10

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部