期刊文献+

Preparation of Hemodialyzer Made from Polyethersulfone Membrane by Dual-bath Coagulation Method

Preparation of Hemodialyzer Made from Polyethersulfone Membrane by Dual-bath Coagulation Method
下载PDF
导出
摘要 The dual-bath coagulation method was used for the preparation of PES membrane in this experiment. The main intent of this stndy was to assess the efforts of gelation conditions on the structures and properties. The dense top layer as well as porous supporting layer can be made by duel-bath coagulation method simultaneous- ly. Different internal quench medium obtained different membrane with different structures. With the increase in time in the first coagulation bath, pure water flux decreased and the clearance rates of urea and creatinine both first increased then decreased and increased slightly in the end. With the temperature of the second coagtdation bath increasing, pure water flux increases and the clearance rates of urea and creatinine first increases then de- creases and increases a little at last. Higher DMSO concentration (wt/wt) in the second coagulation bath results in the increase of pure water flux and the decrease of urea & creatinine clearance rates. The dual-bath coagulation method was used for the preparation of PES membrane in this experiment. The main intent of this stndy was to assess the efforts of gelation conditions on the structures and properties. The dense top layer as well as porous supporting layer can be made by duel-bath coagulation method simultaneous- ly. Different internal quench medium obtained different membrane with different structures. With the increase in time in the first coagulation bath, pure water flux decreased and the clearance rates of urea and creatinine both first increased then decreased and increased slightly in the end. With the temperature of the second coagtdation bath increasing, pure water flux increases and the clearance rates of urea and creatinine first increases then de- creases and increases a little at last. Higher DMSO concentration (wt/wt) in the second coagulation bath results in the increase of pure water flux and the decrease of urea & creatinine clearance rates.
作者 朱思君
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第B12期123-125,共3页 武汉理工大学学报(材料科学英文版)
关键词 dual- bath coagulation gelation conditions polyethersulfone membrane HEMODIALYSIS dual- bath coagulation gelation conditions polyethersulfone membrane hemodialysis
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部