采用分体移动、组装使用的结构而设计的DL-5型移动式整定大直流发生器,解决了低压大直流发生器主变压器中磁感应强度不均匀问题,并且验证了有脉动低压大直流对“直流快速开关”整定的误差公式。
Adopt DL - 5 shift set big-D.C. generator designed with parting shift and combining use structure, solve the problem that magnetic induction intensity is uneven in the main transformer of low-voltage and big-D.C. generator, test and verify the error formula that 'D.C. quick switch' is set by pulsation low-volkge and big-D.C.