国内首台300MW直接空冷半干法脱硫机组,采用的是武汉锅炉厂生产的1045t汽包炉。该炉型采用中储式制粉系统,四角切圆燃烧。运行一年多来,性能较为稳定,但燃烧调整与厂家提供方式已有较大改变,特别是配风调整。为此针对该炉型的一些特点,论述其配风调整方法。
The 1 045 t drum boiler that was manufactured by Wuhan Boiler Factory is adopted in the first Chinese-built 300 MW direct air cooling semi-dry sulfur capture unit. This boiler is designed with bin and feeder system,and diagonal corner tangential firing. For more than a year, its operation is stable, but the adjustment mode of burning has greatly changed,and specially the adjustment of air distribution. There-fore, this paper discusses the adjustment method of air distribution on the basis of considering the characteristics of the boiler.
出处
《华北电力技术》
CAS
2006年第A01期69-73,共5页
North China Electric Power
关键词
四角切圆
配风
调整
燃煤锅炉
diagonal corner tangential firing
air distribution
adjustment
coal-fired boiler