期刊文献+

300MW燃煤锅炉切圆燃烧配风调整

Adjustment of Air Distribution of Tangential Firing for Coal-fired Boiler
下载PDF
导出
摘要 国内首台300MW直接空冷半干法脱硫机组,采用的是武汉锅炉厂生产的1045t汽包炉。该炉型采用中储式制粉系统,四角切圆燃烧。运行一年多来,性能较为稳定,但燃烧调整与厂家提供方式已有较大改变,特别是配风调整。为此针对该炉型的一些特点,论述其配风调整方法。 The 1 045 t drum boiler that was manufactured by Wuhan Boiler Factory is adopted in the first Chinese-built 300 MW direct air cooling semi-dry sulfur capture unit. This boiler is designed with bin and feeder system,and diagonal corner tangential firing. For more than a year, its operation is stable, but the adjustment mode of burning has greatly changed,and specially the adjustment of air distribution. There-fore, this paper discusses the adjustment method of air distribution on the basis of considering the characteristics of the boiler.
出处 《华北电力技术》 CAS 2006年第A01期69-73,共5页 North China Electric Power
关键词 四角切圆 配风 调整 燃煤锅炉 diagonal corner tangential firing air distribution adjustment coal-fired boiler
  • 相关文献

参考文献1

  • 1黄新元编著..电站锅炉运行与燃烧调整[M].北京:中国电力出版社,2003:230.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部