摘要
对国内水内冷汽轮发电机长期运行后普遍存在内冷空心铜导线腐蚀和绝缘引水管堵塞等问题进行了分析,提出了防止铜线圈腐蚀以及水管堵塞的有效方法和措施。
The problems such as corrosion in water - cooled copper wire and blockage of insulation abstraction pipe after long - term operation for domestic water - cooled generator were analyzed, and the effective method and measures to prevent the copper winding corrosion and blockage of water - pipe are put forward.
出处
《电力设备》
2006年第4期76-78,共3页
Electrical Equipment
关键词
水内冷
发电机绕组
铜腐蚀
水管堵塞
water- cooled
genrator winding, copper corrosion