期刊文献+

淄青天然气管道自然电位偏低的原因分析

Cause Analysis on Lower Natural Electric Potencial in Zi-Qing Gas Pipeline
下载PDF
导出
摘要 在淄博-青岛天然气管道阴极保护系统投产前,发现该线的自然电位偏低,低于正常状态的平均值(-0.85V)。对此现象进行了较详细地分析和现场考证,原因是由于缠绕镁带的主管被淹没在水里,形成了牺牲阳极,导致管道电位偏低。通过对套管穿越处进行风干及封堵处理, 电位测试恢复正常。 Prior to getting into operation of cathodic protection system in Zibuo-Qingdao natural gas pipeline, the detected natural electric potencial in this pipeline was lower than -0.85V, the conventional average value. The detailed analysis and site investigation on the phenomenon were conducted. It was founded that the main pipe section wrapped with magnesium strips had been submerged in water so as to form a sacrificial anode,that was the cause of low electric potencial. After air-drying and sealing treatment, the measured electric potencial was in correct range.
出处 《石油工程建设》 2006年第2期32-34,共3页 Petroleum Engineering Construction
关键词 天然气 埋地管道 自然电位 镁牺牲阳极 措施 natural gas buried pipeline natural electric potencial magnesium sacrificial anode analysis
  • 相关文献

参考文献5

  • 1胡士信主编..阴极保护工程手册[M].北京:化学工业出版社,1999:449.
  • 2SY/T 0023-5919-1994,埋地钢质管道干线保护技术管理规程[S]. 被引量:1
  • 3SY/T 0023-1997,埋地钢质管道阴极保护参数测试方法[S]. 被引量:3
  • 4SY/T 0032-2000,埋地钢质管道交流排流保护技术标准[S]. 被引量:12
  • 5SYJ 4006-1990,长输管道阴极保护技术工程施工及验收规范[S]. 被引量:1

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部