摘要
冷水机组是空调系统的主要耗能设备,在实际运行期间,其大多数时间处于部分负荷运行。本文分析了在部分负荷时,调节冷冻水温度和冷却水温度对冷水机组性能的影响,表明在满足舒适性要求和冷水机组正常运行的前提下,适当的提高冷冻水温度和降低冷却水温度可以达到节能的目的。
Water chiller is the main energy consumed appliance, in the fact operation course, which is under part charge function. This paper analyses the infection of accommodating temperature of chilled water and cooling water in part charge and indicates that improving temperature of chilled water and lowering temperature of cooling water can save energy, in the precondition of satisfying comfort request and water chiller's normal condition.
出处
《制冷与空调(四川)》
2006年第1期20-23,共4页
Refrigeration and Air Conditioning
关键词
冷水机组
冷冻水
冷却水
质调节
water chiller
chilled water
cooling water
constant flow control