摘要 目的评估超声内镜引导下Trucut穿刺活检(EUS—TCB)对肾脏组织穿刺活检的有效性及安全性。方法将体重为25~30kg的食用猪,经静脉麻醉后行超声内镜检查及EUS—TCB,穿刺获取的组织标本通过大体及组织学检查,观察获取组织条块的状态,测量组织条块的长度,观察组织中完整肾小球的数量。检查结束后进行动物解剖并观察腹腔内出血状况。结果共对3头猪的肾脏穿刺16次,平均每头穿刺5.3次,13次(81%)穿刺成功获得了肾脏组织;所获得的组织条块中,最长达7mm,最短为0.95mm,平均(3.64±1.73)mm;完整的肾小球数共46个(范围0~10个/次),平均每次穿刺获得的肾小球数为(3.5±2.9)个;大体解剖观察腹腔内未见显著的出血现象。结论EUS—TCB可以安全、有效地对肾脏进行穿刺,并获得满意的’肾组织用于组织病理学观察。 Objective To evaluate the efficiency and safety of acquiring kidney tissue by endoscopic ultrasound-guided Trucut biopsy (EUS-TCB). Methods Under general anesthesia, three 25-30kg swine underwent EUS examination. The kidney biopsy specimens were obtained by EUS-TCB and embedded in paraffin followed by hematoxylin and eosin stain and evaluated histopathologically. The length of tissue and the total number of glomeruli were counted. The animals were sacrificed after EUS-TCB to examine the overt bleeding in their abdominal cavities. Results Histopathological review demonstrated adequate samples representative of the organ biopsied, 81% (13/16) of biopsies provided tissue cores with an average of 5.3 times per each animal. The length of tissue ranges from 0.95-7mm ( mean 3.64 ± 1.73mm) and a total of 46 glomeruli (range:0-10) were obtained with an average of 3.5 ±2.9 per each biopsy. None of the animals developed overt bleeding in their abdominal cavities. Conclusion EUS-TCB is an effective and safe measure to obtain kidney tissue cores for histopathological study.
出处 《中华消化内镜杂志》 2006年第1期46-48,共3页 Chinese Journal of Digestive Endoscopy
关键词 内镜超声检查术 活检 Endoscopic ultrasonography Kidney Biopsy
  • 相关文献

参考文献11

  • 1Chang KJ.Endoscopic ultrasound (EUS) -guided fine needle aspiration (FNA) in the USA.Endoscopy,1998,30:A159-160. 被引量:1
  • 2Gress F,Gottlieb K,Sherman S,et al.Endoscopic ultrasonography-guided fine-needle aspiration biopsy of suspected pancreatic cancer.Ann Intern Med,2001,134:459-464. 被引量:1
  • 3Ribeiro A,Vazquez-Sequeiros E,Wiersema LM,et al.EUS-guided fine-needle aspiration combined with flow cytometry and immunocytochemistry in the diagnosis of lymphoma.Gastrointest Endosc,2001,53:485-491. 被引量:1
  • 4Erickson RA,Sayage-Rabie L,Beissner RS.Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies.Gastrointest Endosc,2000,51:184-190. 被引量:1
  • 5Piccinino F,Sagnelli E,Pasquale G,et al.Complications following percutaneous liver biopsy:a multicentre retrospective study on 68,276 biopsies.J Hepatol,1986,2:165-173. 被引量:1
  • 6Ball AB,Fisher C,Pittam M,et al.Diagnosis of soft tissue tumours by Trucut biopsy.Br J Surg,1990,77:756-758. 被引量:1
  • 7Zinzani PL,Colecchia A,Festi D,et al.Ultrasound-guided coreneedle biopsy is effective in the initial diagnosis of lymphoma patients.Haematologica,1998,83:989-992. 被引量:1
  • 8Hatada T,Ishii H,Ichii S,et al.Diagnostic value of ultrasoundguided fine-needle aspiration biopsy,core-needle biopsy,and evaluation of combined use in the diagnosis of breast lesions.J Am Coll Surg,2000,190:299-303. 被引量:1
  • 9Levy MJ,Jondal ML,Clain JE,et al.Preliminary experience with an EUS-guided trucut biopsy needle compared with EUS-guided FNA.Gastrointest Endosc,2003,57:101-106. 被引量:1
  • 10Levy MJ,Wiersema M J,Clain JE,et al.Comparison of endoscopic ultrasound-guided trucut biopsy (EUS-TCB) to endoscopic ultrasound-guided fine needle aspiration (EUS-FNA).Gastrointest Endosc,2003,57:AB244. 被引量:1

同被引文献17

  • 1欧阳涛,李金锋,王天峰,解云涛,范照青,林本耀.原发性乳腺癌经皮病灶穿刺组织病理学检查临床应用研究[J].中华外科杂志,2005,43(23):1519-1521. 被引量:11
  • 2朱小英,董雄伟,孙波,沈树权,杨道华,黄江,吴云林.超声内镜引导下Trucut穿刺活检诊断上消化道黏膜下肿瘤的初步经验[J].中华消化内镜杂志,2006,23(3):172-174. 被引量:5
  • 3马艳艳,刘晓勇,吴洪儒,王凤光,汪育苗.涎腺肿块的细针吸取细胞学诊断研究[J].北京口腔医学,2007,15(2):95-98. 被引量:6
  • 4Gress F, Gottlieb K, Sherman S, et al. Endoscopic uhrasonography-guided fine-needle aspiration biopsy of suspected pancreatic cancer. Ann Intern Med,2001,134 :459-464. 被引量:1
  • 5Vilmann P, Puff R. Endoscopic ultrasound-guided fine needle aspiration and Tin-cut biopsy. Tech Gastrointest Endosc,2007, 9:2-19. 被引量:1
  • 6Levy MJ, Jondal ML, Clain J, et al. Preliminary experience with an EUS-guided Tin-cut biopsy needle compared with EUS-guided FNA. Gastrointest Endosc ,2003,57 : 101-106. 被引量:1
  • 7Levy M J, Wiersema MJ. EUS-guided Tru-cut biopsy. Gastrointest Endosc ,2005,62:417-426. 被引量:1
  • 8Larghi A, Verna EC, Stavropoulos SN, et al, EUS-guided Trucut needle biopsies in patients with solid pancreatic masses a prospective study. Gastrointest Endosc,2004,59 : 185-190. 被引量:1
  • 9Saftoiu A, Vilmann P, Guldhammer S B,et al. Endoscopic ultra- sound (EUS)-guided Tru-cut biopsy adds significant information to EUS-guided fine-needle aspiration in selected patients: a prospective study. Scand J Gastroenterol,2007,42 : 117-125. 被引量:1
  • 10Storch I, Jorda M, Thurer R,et al. Advantage of EUS Tru-cut biopsy combined with fine-needle aspiration without immediate on-site cytopathologic examination. Gastrointest Endosc, 2006, 64:505-511. 被引量:1

引证文献2