KTA-2型常温脱砷剂在小本体聚丙烯装置的应用 被引量:1

Application of KTA-2 Type Normal Temperature Arsenic Removal Catalysts in the Small Polypropylene Equipment
下载PDF
导出
摘要 分析了引起聚丙烯装置异常波动的原因,并确定是丙烯原料中杂质砷含量偏高所致。将原干燥塔内的分子筛更换为KTA-2型常温脱砷剂作为脱砷塔使用。脱砷装置投用后,降低了催化剂、活化剂的消耗量,提高了反应的稳定性,取得了较好的效果。 Unusual trouble of the polypropylene equipment is analyzed to confirm that it is cased by the high impurity of arsenic in the raw material propylene.KTA-2 type normal temperature arsenic removal catalysts are used in stead of molecule sieve in the original dry tower, which is to be used as arsenic removal tower. When the arsenic removal equipment is put into use, consumption of catalysts and activation agents are reduced, improving the stability of the reaction with good results.
作者 卞明辉
出处 《化工生产与技术》 CAS 2006年第1期33-35,共3页 Chemical Production and Technology
关键词 聚丙烯 脱砷剂 应用 polypropylene arsenic removal catalyst application