期刊文献+

轴承盖超声波探伤缺陷分析及改进 被引量:1

Analysis and Improvement on UT Defects of Certain Type of Bearing Caps
下载PDF
导出
摘要 某型轴承盖轴承面经超声波探伤不合格。经分析主要原因是原工艺热冒口的冒口颈(内浇道)偏小,且开设的位置不合理,造成内浇道根部存在疏松和晶粒粗大铸造缺陷。新工艺利用均衡凝固理论,采用短、薄、宽内浇道分散引入,配合冷铁和保温冒口,加大激冷度,强化补缩;优化熔化工艺,改善内部组织;获得了高致密度要求的铸件。 The main reasons that result in the disqualification of bearing caps, bearing surface and UT is that the riser neck of primary hot feeder is too small and their positions are not reasonable so as to cause porosity and coarse grain in the root of riser neck. Based on the new equilibrium solidification theory, the dispersed gate with flat.thin and wide rise neck, coupled with cold iron and warming riser, was adopted in the new gating system. The system can increase chill degree, strengthen feeding, improve inner structure, and thus acquire desired castings with higher density.
出处 《铸造技术》 EI CAS 北大核心 2006年第1期29-30,共2页 Foundry Technology
关键词 轴承盖 超声波探伤 均衡凝固 Bearing caps UT Proportional solidification
  • 相关文献

参考文献3

二级参考文献6

共引文献16

同被引文献1

  • 1戚墅堰机车车辆工厂.稀土球铁柴油机轴承盖[J].中国铸造装备与技术,1971(4). 被引量:1