摘要 目的:评价紧闭环路系统在新生儿麻醉应用中的安全性有效性。方法:53例新生儿手术,在全身麻醉气管插管后,行机械定压模式呼吸通气30min,监测通气前后动脉血气值、SpO2、体温、PetCO2、气道压、呼吸频率、心电等参数。结果:新生儿手术全身麻醉控制呼吸,根据PetCO2适当调节呼吸参数,采用定压呼吸模式,能够维持PaO2、PaCO2于正常范围。结论:紧闭环路系统能安全有效地应用于新生儿手术。
出处 《实用医学杂志》 CAS 2006年第2期163-164,共2页 The Journal of Practical Medicine
  • 相关文献

参考文献6

  • 1GEBHARD R, WEISER U K. Minimal flow anesthesia in newborn infants-advantages and risks [J]. Anaesthcsol Reanim, 1999; 24(1 ):41. 被引量:1
  • 2TOBIN M J, STEVENSON G W, HOM B J, et al. A comparison of three models of ventilation with the use of an adult circle system in an infant lung model [ J ]. Anesth Analg, 1998, 87 (3) : 766. 被引量:1
  • 3BAURN J. Clinical applications of low flow and closed circuit anaesthesia [J]. Acta Anaesthesiol Belg, 1990, 41(2): 239. 被引量:1
  • 4CHHIBBER A K, FICKLING K, KOLANO J W. Comparison of endtidal and arterial carbon dioxide in infants using laryngeal mask airway and endotracheal tube. Anesth Analg, 1997, 84 (1):51. 被引量:1
  • 5安刚 薛富善 主编.现代麻醉学技术[M].北京:科学技术文献出版社,2001.8. 被引量:109
  • 6张奉超.新生儿麻醉中保温方法的探讨[J].中原医刊,2002,29(11):11-12. 被引量:12

二级参考文献1

共引文献118

同被引文献22

  • 1郑利民,李玉梅.紫绀与非紫绀型先天性心脏病患者P_(ET) CO_2与PaCO_2的相关性[J].临床麻醉学杂志,2005,21(6):377-378. 被引量:12
  • 2李静,马维根.呼气末二氧化碳分压监测在小儿全麻中的应用[J].天津医药,2006,34(11):820-820. 被引量:3
  • 3安刚,薛富善,主编.现代麻醉学技术,北京:科学技术文献出版社,2001,467. 被引量:22
  • 4肖辉,佘守章,许立新.不同类型心脏患者心内直视手术期间呼气末CO2分压与动脉血CO2分压及其差值的变化[J].现代临床医学生物工程学杂志,2007,13(2):85-87. 被引量:2
  • 5Sivarajan VB, Bohn D. Monitoring of standard hemodynamlc pa- rameters: heart rate, systemic blood pressure, atrial pressure, pulse oximetry, and end-tidal CO2 [ J]. Pediatr Crit Care Med, 2011, 12 (4): S2-S11. 被引量:1
  • 6Heines SJ, Strauch U, Roekaerts PM, et al. Accuracy of end- tidal CO2 capnometers in post-cardiac surgery patients during controlled mechanical ventilation[ J]. J Emerg Med, 2013,45 (1) :130-135. 被引量:1
  • 7Zhang C, Wang M, Wang R, et al. Accuracy of end-tidal CO2 measurement through the nose and pharynx in nonintubated pa- tients during digital subtraction cerebral angiography[J]. J Neu- rosurg Anesthesiol, 2013,25 (2) : 191-196. 被引量:1
  • 8Razi E, Moosavi GA, Omidi K, et al. Correlation of end-tidal carbon dioxide with arterial carbon dioxide in mechanically venti- lated patients [ J ]. Arch Trauma Res, 2012,1 (2) : 58-62. 被引量:1
  • 9Cinar O, Acar YA, Arziman I, et al. Can mainstream end- tidal carbon dioxide measurement accurately predict the arterial carbon dioxide level of patients with acute dyspnea in ED[J]. Am J Emerg Med,2012,30(2) :358-361. 被引量:1
  • 10Trevisanuto D, Giuliotto S, Cavallin F, et al. End-tidal carbon dioxide monitoring in very low birth weight infants: correlation and agreement with arterial carbon dioxide[ J]. Pediatr P ulmonol, 2012,47 ( 4 ) : 367-372. 被引量:1