摘要 目的探讨加压滑动鹅头钉治疗股骨转子下粉碎性骨折的疗效。方法对21例股骨转子下粉碎性骨折,采用加压滑动鹅头钉内固定,同时植骨。结果21例中优14例,良6例,差1例,优良率95.2%。经1~3年随访,21例骨折愈合,髋关节活动良好。结论加压滑动鹅头钉内固定是治疗股骨转子下粉碎性骨折比较理想的方法。 Objective To investigate the curative effect of dynamic hip screw(DHS )for treatment of femoral subtrochanteric comminuted fracture. Methods Twenty-one cases of subtrochanteric comminuted fracture were performed with DHS and bone graft simultaneously. Results Follow-up of one to three years, All patients were union of fracture and their hip-joint function was well. Conclusion DHS internal fixation is an ideal measure to treat subtrochanteric comminuted fracture.
作者 陈兆兴
出处 《新乡医学院学报》 CAS 2006年第1期79-80,共2页 Journal of Xinxiang Medical University
关键词 加压滑动鹅头钉 内固定 股骨转子下骨折 粉碎性骨折 dynamic hip screw internal fixation femoral subtrochanteric fracture comminuted fracture
  • 相关文献

参考文献5

二级参考文献14

共引文献71

同被引文献27

  • 1陆晴友,吴岳嵩,王成焘.股骨近端解剖形态的CT三维重建与分析[J].第二军医大学学报,2005,26(9):1029-1033. 被引量:37
  • 2肖湘,张铁良.股骨转子下骨折内固定失败原因分析[J].中华骨科杂志,2006,26(3):187-190. 被引量:73
  • 3刘振宇,刘长贵,李强.PFN与DCS治疗股骨转子下骨折的生物力学研究[J].中国骨与关节损伤杂志,2006,21(12):971-973. 被引量:44
  • 4吴雪晖,王序全,谢肇,马树枝,张劲松.股骨近端髓内针治疗股骨粗隆间骨折的疗效评估[J].第三军医大学学报,2007,29(7):617-619. 被引量:19
  • 5McConnell A,Zdero R,Syed K,et al.The biomechanics of ipsilateral intertrochanteric and femoral shaft fractures:a comparison of 5 fracture fixation techniques[J].J Orthop Trauma,2008,22(8):517. 被引量:1
  • 6Hasenboehler EA,Agudelo JF,Morgan SJ.Treatment of complex proximal femoral fractures with the proximal femur locking compression plate[J].Orthopedics,2007,30(8):61. 被引量:1
  • 7Szulc P,Munoz F,Duboeuf F,et al.Low width of tubular bones is associated with increased risk of fragility fracture in elderly men--the MINOS study[J].Bone,2006,38(4):595. 被引量:1
  • 8Roberts JW,Grindel SI,Rebholz B,et al.Biomechanical evaluation of locking plate radial shaft fixation:unicortical locking fixation versus mixed bicortical and unicortical fixation in a sawbone model[J].J Hand Surg Am,2007,32(7):971. 被引量:1
  • 9Ahmad M,Nanda R,Bajwa AS,et al.Biomechanical testing of the locking compression plate:when does the distance between bone and implant significantly reduce construct stability[J].Injury,2007,38(3):358. 被引量:1
  • 10Kumar AJ,Parmar VN,Kolpattil S,et al.Significance of hip rotation on measurement of "Tip Apex Distance" during fixation of extracapsular proximal femoral fractures[J].Injury,2007,38(7):792. 被引量:1

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部