总结了目前砖砌体建筑普遍存在着竖向、水平、斜向温度裂缝,并分析了裂缝产生原因。根据裂缝产生的不同原因,在建筑、结构设计时采取“调”、“放”、“抗”措施,达到控制裂缝产生的目的。
The horizontal, vertical or oblique thermal cracks widely present in a masonry structure are summarized in this paper. The reasons for these cracks are analyzed.On basis of these causes, different methods called' readjusting', 'releasing' and 'resisting' for short, can be taken respectively in structure design to eliminate the cracks.
出处
《重庆建筑大学学报》
CSCD
1996年第1期100-104,共5页
Journal of Chongqing Jianzhu University
关键词
砖砌体建筑
温度裂缝
设计控制
s: masonry struture
thermal crack control
design control for the crack