摘要 分析了用MFL法检测管道缺陷时缺陷漏磁信号分辨率的特征,设计计算机控制的管道漏磁场分布测试系统检测、分析管道内漏磁场,优化设计用于小管径、厚管壁海底管道(273×12.7)缺陷检测的磁铁节,在此基础上设计制造了海底管道缺陷在线智能检测机器人,实验验证了机器人对人工模拟缺陷的检测能力。 The resolution of the flux leakage signals of defect in pipe are studied theoretically. The flux leakage fields inside pipe are measured precisely by the compute-controlled measurement system. Three magnet systems, which magnetize the small-diameter and thick wailed subsea pipe, are designed and tested. The desirable magnet system is used to make the smart pig. The ability of the MFL pig to characterize the depth, shape and length of varied defects is evaluated by detecting different aritifical defects.
出处 《传感技术学报》 CAS CSCD 北大核心 2005年第4期818-821,共4页 Chinese Journal of Sensors and Actuators
基金 国家863高科技资助项目(2002AA324040)
关键词 漏磁场 管道缺陷检测 小管径 厚管壁海底管道 flux leakage fields defect inspection small-diameter and thick walled subsea pipe
  • 相关文献

参考文献7

  • 1Takeda Minkov D,Shoji Y,Lee T,J Estimating the sizes of surface cracks based on Hall element measurements of the leakage magnetic field and a dipole model of a crack[J].Applied Physics A:Materials Science and Processing,2002,74(2):169-176. 被引量:1
  • 2Catalin Mandache and Lynann Clapham.A model for magnetic flux leakage signal predictions[J].Canada J Phys D:Appl Phys,2003,36:2427-2431.Beuker,Thomas,Brown,Bryce. 被引量:1
  • 3Coughlin C R,Clapham L,Atherton D L.Effects of stress on MFL responses from elongated corrosion pits in pipeline steel[J].NDT&E International,2000,33:181-188 被引量:1
  • 4Afzal M,Polikar R,Udpa L,Udpa S.Adaptive noise cancellation schemes for magnetic flux leakage signals obtained from gas pipeline inspection[C].In:2001 IEEE International Conference (ICASSP '01).2001,6:3389-3392. 被引量:1
  • 5Gwan Soo Park,Eun Sik Park.Improvement of the sensor system in magnetic flux leakage-type nondestructive testing (NDT)[J].IEEE transactions on magnetics.2002,38:1277-1280. 被引量:1
  • 6Foerster.new findings in the field of nondestructive magnetic leakage field inspection[J].NDT international.1986,19:3-14. 被引量:1
  • 7Nestleroth J B,Bubenik T A.Magnetic Flux Leakage (MFL) Technology For Natural Gas Pipeline Inspection[M].National technical information center.1999,2724-2777. 被引量:1