介绍了以镍板为阳极,不锈钢为阴极恒电位电解法去除HF中微量水分的方法.用卡尔—费休法对处理后的HF的含水量进行测定,结果表明,随着电解时间的延长,电解电流和氟化氢中的水分含量逐渐减小,最后达到一定值.
The method with a falcial anode, stainless steel cathode and constant pressure to get rid of little water in HF is introduced. The worked HF was measured with Karl-Fischer titration method. The results showed that when the state of anode is constant, the current water content of worked HF decrease with the electrolysis and reach the last content.
出处
《南开大学学报(自然科学版)》
CAS
CSCD
北大核心
2005年第5期62-64,共3页
Acta Scientiarum Naturalium Universitatis Nankaiensis
基金
2005年天津科技攻关培育项目(05YFGPGX05600)
关键词
恒电位电解
微量水
卡尔-费休法
constant pressure electrolysis
little water
Karl-Fischer method