期刊文献+

HL-2A装置快速扫描气动探针的研制和运用 被引量:3

Manufacture and application of fast-scanning probe system in the HL-2A tokamak
下载PDF
导出
摘要 快速扫描气动探针已在HL-2A装置上用于对边缘等离子体参数的径向分布的测量,特别是刮离层等离子体参数的特征长度和扰动的测量。该系统采用精密的气动气缸驱动带有探针组件的长驱动杆,其最快速度可在60 ms时间内水平扫描8 cm的距离。探针信号测量具有1MHz的快速时间响应和0.04 mm的空间分辨率。可靠地测量了HL-2A装置边缘电子温度和密度的时空分布。 A fast-scanning probe system has been installed in the HL-2A tokamak and is used to measure the edge and scrape-off layer (SOL) plasma parameter profiles, especially the characteristic length and fluctuations of local plasma parameters. The system has a compact pneumatic cylinder and the pneumatic cylinder can drive a long drive shaft with the probe array. The system can scan a horizontal distance of 8 cm in 60 ms. The SOL and edge plasma parameter profiles with spatial resolution 0.04 mm have been obtained with a digital grating displacement measurement system.
出处 《核聚变与等离子体物理》 EI CAS CSCD 北大核心 2005年第4期241-245,共5页 Nuclear Fusion and Plasma Physics
关键词 快速扫描气动系统 数据光栅位移系统 气动汽缸 A fast-scanning system Digital grating displacement system Pneumatic cylinder
  • 相关文献

参考文献4

  • 1Asakura N, Tsuji-jio S, Lkeda Y, et al. Fast reciprocating probe system for local scrape-off layer measurements in front of the lower hybrid launcher on JT-60U [J]. Bey. Sci. Instrum., 1995,66(12) :5428. 被引量:1
  • 2洪文玉,严龙文,钱俊,潘宇东,罗萃文,徐征宇,潘莉,袁保山.HL-2A偏滤器运行模式的探针测量[J].核聚变与等离子体物理,2005,25(1):69-73. 被引量:1
  • 3洪文玉,严龙文,王恩耀,潘宇东,钱俊,李伟,崔正英,罗萃文.HL-2A装置的边缘参数测量[J].核聚变与等离子体物理,2005,25(3):168-172. 被引量:4
  • 4Pitcher C S, Stangeby P C. Experimental divertor physics[J]. Plasma Phys. Contr. Fusion, 1997, 39 (6) :779. 被引量:1