摘要
F1系列 PLC 可以利用其 F2-6A 模块,将传感器对物理量转换后的模拟电压信号采集输入到 PLC 中,本文重点阐述了对输入到PLC 中的数据进行整定运算的算法和处理程序,以及输出显示的思路和方法,并以温度控制为例介绍了处理的详细过程。
The FI series PLC can use its F2-6A module to accept the analogue signals to PLC that are converted from the phyieal signal by sensor, the article emphatically introduced the algorithm and processing procedure of the data that is inputed to PLC, idea and method of the data display. And taking temperature control as example introduced detailed procedure of data processing.
出处
《电气自动化》
北大核心
2005年第6期65-66,69,共3页
Electrical Automation
关键词
可编程控制器(PLC)
模拟量
输入/输出
运算
显示
programmable Logical Control(PLC), analogue signal ,input/output ,operation ,display