摘要 介绍了在该仪器上测量折射率值小于1.76和大于1.76的两种测量方法,给出了以计算机为核心的宽光谱高精度折射率全自动测量仪的基本组成、主要误差源和测控软件的一级数控流图,用该仪器对包括红外材料锗在内的多种样品进行了测量并给出了部分测量结果,结果表明:在365.0nm至2600nm和2600nm至10600nm的波长范围内分别获得了优于±3×1-0 6和±2×1-0 4的测量精度。 It presents two kinds of measurement methods of refractive index above 1.76 or below 1.76 using the photo-electric refractometer. Basic constituent and principal error sources of computerized photo-electric automatic refractometer with broad spectral range and high accuracy are introduced. The diagram of 1st grade datacontrol flow of software for instrument measuring and controlling is also introduced. The refractive indices of different optical samples and germanium belong in infra-red materials are measured with this instrument and the measuring results of samples in part are given. The experimental results show that measuring uncertainty is better than ± 3 × 10^-6 or ± 2 × 10^-4 in the wavelength ranges of 365 to 2600nm and 2600 to 10600nm respectively.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2005年第11期1159-1162,共4页 Chinese Journal of Scientific Instrument
关键词 高精度 折射仪 误差源 自动测量 High accuracy Refractometer Error source Auto-measuring
  • 相关文献

参考文献9

  • 1Debenham Mary,Dew G D,Putland D E.An improved recording refractometer for optical glasses in the wavelength range 300 to 2600 nm.Optica Acta,1979,26(12):1487~1503. 被引量:1
  • 2Wood D L,Fleming J W Jr..Computerized refractive index measure for bulk materials at UV,visible and IR wavelengths.Rev.Sci.Instrument,1982,53(1):43~47. 被引量:1
  • 3Heidenhain J.Das neue prazisions-gonimeter zur brechzahlmessung in der physikalisch-technischen bundesanstalt.Meβtechaische Information,Ausgabe,Marz,1980,8. 被引量:1
  • 4Karny Z,Kafri O.Refractive index measurement by more deflectometry.Appl.Opt.,1982,21(18):3326~3328. 被引量:1
  • 5Edwin R P,Dudermel M T,Lamare M.Refractive index measurement of ten germanium samples.Appl.Opt.,1982,21(5):878~881. 被引量:1
  • 6Bhattacharya J C.Refractive index measurement.Optics and Laser Technology,1987,19(1):29~32. 被引量:1
  • 7苏大图 朱秋东.一种高精度测量光学玻璃折射率和色散的方法[A]..全国光学测试学术交流会论文[C].南京,1998-8.. 被引量:1
  • 8宋克非.高精度光电自动折射仪的瞄准方法及其实现[J].光学精密工程,1999,7(4):100-104. 被引量:3
  • 9苏大图主编..光学测量[M].北京:机械工业出版社,1988:278.

二级参考文献8

共引文献2

同被引文献52

引证文献9

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部