期刊文献+

模拟机及CT导引经皮肺穿并发症的防治 被引量:1

Study on the Prevention and Treatment of Complications in the Transthoracic Needle Biopsy of Lung under Simulator and Computer Tomography
原文传递
导出
摘要 目的探索模拟机及CT导引经皮肺穿并发症的防治。方法模拟定位机导引经皮肺穿300例,CT定位经皮肺穿50例。结果穿刺后气胸发生率分别为7%和6%;出血发生率分别为16.6%和14%。结论模拟机及CT导引经皮肺穿,掌握好适应证,医、护、技、患密切配合,并发症可降到最低,一旦发生并发症积极处理可痊愈。 Objective To explore the prevention and treatment of complications in the transthoracic needle biopsy of lung under simulator and computer tomography(CT). Methods Three hundred patients were received simulator-guided transthoracic needle biopsy of lung and 50 patients were received CT-guided operation. Results Under the simulator-guided and CT-guided transthoracic needle biopsy of lung, the rates of pneumothorax were 7% and 6% respectively, and the rates of hemorrhage were 16. 6% and 14% respectively. Conclusion Simulator and CT guided percutaneous transthoracic were safe and fast for diagnosis with high accuracy for pulmonary lesions. It was very important for the doctors, nurses, technicans and patients in close cooperation to prevent and treat the complications in the transthoracic needle biopsy of lung under simulator and CT.
作者 付尚志
出处 《中国医师杂志》 CAS 2005年第10期1336-1337,共2页 Journal of Chinese Physician
关键词 经皮肺穿 并发症 防治 CT导引 模拟机 气胸发生率 模拟定位机 CT定位 适应证 Transthoracic needle biopsy Complication Prevention and cure
  • 相关文献

参考文献4

二级参考文献18

  • 1周际昌.实用肿瘤内科学[M].北京:人民卫生出版社,2000.487-488. 被引量:32
  • 2Dennie CJ,Matzinger FR,Marriner JR,et al.Transthoracic needle biopsy of the lung: results of early discharge in 506 outpatients.Radiology,2001 ,219:247-251. 被引量:1
  • 3Swischuk JL,Castaneda F,Patel JC,et al.Percutaneous transthoracic needl e biopsy of the lung: review of 612 lesions.J Vasc Interv Radiol,1998 ,9:347 -352. 被引量:1
  • 4Charig MJ,Phillips AJ.CT-guided cutting needle biopsy of lung lesions -s afety and efficacy of an out-patient service.Clin Radiol,2000,55:964-969 . 被引量:1
  • 5Laurent F,Latrabe V,Vergier B,et al.CT-guided transthoracic needle bio ps y of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge c oaxial cutting needle.Clin Radiol ,2000 ,55:281-287. 被引量:1
  • 6Yankelevitz DF,Vazquez M,Henschke CI.Special techniques in transthoracic needle biopsy of pulmonary nodules.Radiol Clin North Am,2000 ,38:267-279. 被引量:1
  • 7Klein JS,Zarka MA.Transthoracic needle biopsy.Radiol Clin North Am,2000,38:235-266. 被引量:1
  • 8Rozenblit AM,Tuvia J,Rozenblit GN,et al.CT-guided transthoracic needle b io psy using an ipsilateral dependent position.AJR Am J Roentgenol,2000,174:17 59-1764 . 被引量:1
  • 9Kodama F,Ogawa T,Hashimoto M,et al.Fatal air embolism as a complication of CT-guided needle biopsy of the lung.J Comput Assist Tomogr,1999,23:949 -951. 被引量:1
  • 10林冬梅 秦德兴 刘尚梅.肺纵隔细针穿刺应用与病理分析[J].实用肿瘤杂志,1998,4(2):187-187. 被引量:1

共引文献159

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部