本文详细论述了差压变送器测液面迁移的原理,并结合经验给出了带迁移的差压变送器故障的具体分析方法。
This article discusses in particular removal principle of the difference pressure transmitter while measuringjuice panel, and gives specific assaying methodology of malfunction with migration incorporating with author' experiences.
出处
《中国仪器仪表》
2005年第9期105-106,109,共3页
China Instrumentation
关键词
差压
变送器
迁移
差压变送器
Difference pressure Transmitter Migration