介绍了以电流互感器油色谱跟踪分析为主并结合运行工况的状态诊断方法,来准确地判断电流互感器的局部放电性故障,并进一步分析故障产生原因,提出改进措施,对相关专业人员有一定的借鉴意义。
The partial discharge fault of current transformer could be precisely judged through current transformer oil chromatography tracking analysis and status diagnosis of operation condition, and then the reasons caused fault were analyzed, some improving measures were presented for relevant specialized personnel's reference.
出处
《黑龙江电力》
CAS
2005年第5期366-367,371,共3页
Heilongjiang Electric Power
关键词
电流互感器
色谱分析
局部放电
绝缘材料
故障诊断
current transformer
chromatograph analysis
partial discharge
insulation material
fault analysis