摘要
揭示了积分移相法原理测量无功功率的相角误差问题,提出一种简便的解决方法,并对最后实用模型的性能,诸如采样频率影响,频率响应特性等进行了分析。
This paper introduces the phase error caused by the phase shift method in initial stages using integral for reactive power measurement and puts forward a solution. The characteristic of a practically available model are discussed, such as the effect of sample frequency, frequency response and etc.
出处
《电测与仪表》
北大核心
2005年第10期5-7,共3页
Electrical Measurement & Instrumentation
关键词
无功功率测量
相角误差
积分移相法
reactive power measurement
phase error
the phase shift method based on integral