摘要
在六开关三相异步发电系统中增加较少的硬件,可实现对常见故障的容错,容错后系统重构为四开关三相运行系统。研究了容错型四开关三相系统中电压矢量的特点及其对磁链和转矩的调节作用,提出了四开关三相系统瞬时转矩控制中磁链和转矩的控制方案。对四开关三相异步发电系统的几个关键问题进行了研究,针对电容电压漂移问题,提出了修正转矩给定的有效方法。最后给出了仿真与实验结果。
In the six-switch three-three induction generation system, a few usual fault modes can be tolerated by increasing some low cost hardware. The system is reconfigurated as a four-switch three-phase generation system after the short-circuit or open-circuit fault of a power switch has been detected and isolated. Features of voltage space vectors of the tolerant four-switch system are analyzed. The adjust effect of different voltage vectors to flux linkage and torque is investigated. Control scheme of flux linkage and torque in instantaneous torque control(ITC) of four-switch three-three system is proposed. Several key problems of four-switch threephase system are researched. An effective method to restrain voltage excursion of two capacitors by modifying the torque command is presented. Simulation and experimental results are presented finally.
出处
《航空学报》
EI
CAS
CSCD
北大核心
2005年第5期567-573,共7页
Acta Aeronautica et Astronautica Sinica
基金
国家自然科学基金(50177014)教育部博士学科点专项科研基金(20010287001)资助项目