期刊文献+

新旧HP.Nb炉管焊接后剩余寿命评价 被引量:5

Residual life assessment on the reformer tube welded with serviced and new HP.Nb material
下载PDF
导出
摘要 制氢转化炉在石化行业中应用广泛,作为关键设备的转化炉炉管,由于服役温度高,一般采用离心铸造的HK40或HP.Nb高温合金。当制氢转化炉炉管发生局部失效时,采用局部更换炉管方法可延长整根炉管的使用寿命。文中分别采用微观组织分级法、基于硬度测量的寿命预测方法以及Larson-Miller参数法对新旧HP.Nb炉管焊接后的寿命进行综合评价,研究结果表明新旧炉管焊接后的剩余寿命约为4.5×104h,蠕变断裂发生在旧母材处。 Reformer furnaces are widely used in petrochemical industry, and the furnace tubes are one of the key components. Because of serving under high temperature, centrifugally casted HK40 or HP. Nb high temperature alloys are generally used. When a reformer furnace tube locally failed, the whole furnace tube service life will be extended by replacing the failed furnace tube. In this paper, the methods of micro-structure ranking, life prediction based on hardness measurement and Larson-Miller parameter were respectively used to synthetically evaluate the residual life of the welded tube with the new and serviced HP. Nb materials. Research results show that the residual life of the welded tube with the new and serviced materials is about 4. 5×10^4 hours and creep rupture will take palace at serviced base metal.
出处 《南京工业大学学报(自然科学版)》 CAS 2005年第4期32-36,共5页 Journal of Nanjing Tech University(Natural Science Edition)
基金 中石化科技开发项目(303040)
关键词 高温 制氢转化炉炉管 剩余寿命评价 焊接 high temperature reformer furnace tube residual life assessment welding
  • 相关文献

参考文献7

  • 1巩建鸣,涂善东,陈嘉南,徐平,潘文越,郭建文.制氢转化炉炉管长期服役后损伤评价[J].南京化工大学学报,1999,21(1):49-53. 被引量:23
  • 2American Petroleum Institute. Calculation of heater-tube thickness in petroleum refineries: API recommended practice 530, 3rd ed [M]. Washirgton:D C, 1998. 被引量:1
  • 3Neubauer D B. Creep damage evaluatin in power plant[A]. Proceeding of the Second International Conference on Creep and Fracture of Engineer in Structures (Part2)[C]. Swansea UK: Pineridge Press, 1984. 215-217. 被引量:1
  • 4I Le May, TC da Silveira , CH Vianna. Criteria for the evaluation of damage and remaining life in reformer furnace tubes [J]. Int J Pres Ves & Piping, 1996, 66 (1-3): 233-241. 被引量:1
  • 5Gong J M,Tu S T, Yoon K B. Damage assessment and maintenance strategy of hydrogen reformer furnace tubes [J]. Engineering Failure Analysis,1999, 6: 143-153. 被引量:1
  • 6王富岗 王来.运行4×104万h的HK40转化炉炉管的研究及其剩余寿命预测[A]..石油化工装置失效分析论文选集 [C].大连: 大连理工大学出版社,1991.. 被引量:1
  • 7Viswanathan R,Fould J.Accelerated stress rupture testing for creep life prediction-its value and limitation [J].ASME Trans J Press Ves Tech,1998,120:105-11. 被引量:1

二级参考文献5

  • 1巩建鸣,南京化工大学-中石化失效分析与预防研究中心研究报告,FAP-HTT9705,1997年 被引量:1
  • 2王富岗,石油化工装置材料及其损伤,1991年 被引量:1
  • 3钱家麟,管式加热炉,1987年 被引量:1
  • 4林英,化工机械,1986年,5期,44页 被引量:1
  • 5武川哲也,化工机械,1979年,1期,43页 被引量:1