摘要
介绍了非能动安注箱的设计与实验,并用CATHENA程序分析其特性:注入流量的峰值,高注入流量的持续时间,最低注入流量等。计算结果表明非能动安注箱设计满足主要的性能要求,CATHENA程序计算结果与实验数据基本一致,可用于概念设计与事故分析。
The design and the test facility of passive safety injection tank are introduced. The code of CATHENA is used to analyse the characteristic of fluidic device., peak discharge flow rate, duration of high flow rate, minimum discharge flow rate. The calculated results show that the passive SIT meets its primary performance requirements. A comparison between the calculated results and the experimental data shows a good match, so CATHENA code can be used as a tool for conceptual design and accident analysis.
出处
《核科学与工程》
CSCD
北大核心
2005年第2期149-153,共5页
Nuclear Science and Engineering