摘要
利用加速器单能中子源测量了3和14MeV中子在厚度为0一6cm的较大铁板中的穿透率,测量表明在一定范围内中子衰减可近似用指数规律描述,指数因子低于宏观截面。测量结果与Monte-Carlo模拟计算大致符合。
The penetrability of 3 and 14MeV neutron passing through Fe slabs with thickness of 0一6cm is measured.The experimental resuIts can be aproximatively described by exponential func-tion in fixed range. The exponential factor is lower than macroscopic cross section and the experi-mental data are approximately in agreement with Monte-Carlo calculations.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
1995年第4期313-314,共2页
Atomic Energy Science and Technology