摘要
对烧结炉中20g钢冷却管爆裂所进行的检验确认爆裂原因是冷却水量小及水质差引起堵塞,造成过热过烧。建议软化水质和改进冷却系统为解决途径。
The bursting of 20g steel for cooling pipe in sintering furnace was the result of pipe blocking, over-heating and over-burning caused by inferior water quality and inadequate water quantity. The proposed solution is to soften the water and improve the cooling system.
出处
《上海金属》
CAS
1995年第6期48-52,共5页
Shanghai Metals
关键词
烧结炉
冷却管
失效分析
冷却水
Cooling pipe for sintering furnace, Failure Analysis, Cooling Water