摘要
为解决水电站规划设计与水轮机运行特性之间的矛盾,分析了在高水头下可能引起的机组运行问题,以及采用设置最大出力作为预防措施在技术上的可行性和对工程的影响,对清江水布垭电站机组设置最大出力的设计优化进行了介绍。
In this paper, based on the inconsistency between the planning design of power station and operating performance of hydro-turbine, the technical feasibility and influence on engineering practice of the maximum output setting (MOS) as a solution have been studied; and the optimizing design on MOS of ShuiBuYa power station unit was introduced。
出处
《水力发电》
北大核心
2005年第7期70-71,82,共3页
Water Power
关键词
水电站设计
参数优化
最大出力
水布垭电站
hydroelectric power station design
parameter optimization
MOS
Shuibuya Hydropower station