期刊文献+

射线平板探测器成像系统的数理模型 被引量:3

Mathematical model based on X-ray imaging system of flat panel detector
原文传递
导出
摘要 非晶硅X射线数字平板探测器是目前唯一可取代胶片照相的新型技术,对其成像特性的研究已成为高像质的DR和三维CT检测技术的基础。目前X射线成像系统均是以线性时不变理论作为分析基础的。基于X射线平板探测器成像系统、成像机理和几何参数建立了成像系统的点扩展函数(PSF)。用圆柱体等效二维PSF模型,使成像系统退化为比例系统,从而把复杂的反卷积运算转化成用代数方程来求解,能够快速实现通过探测器输出图像来估计透照工件的二维输入图像。此模型的建立为在实际检测中利用输出的图像通过线性变换得到输入估计。在DR系统中,基于上述数理模型建立了灵敏度模型,利用输出场强可以很好的再现输入场强。 The linearity time-invariant theory was based on analyze the X-ray imaging system. So it was the imFotent to analyze the point spread function (PSF). Based on the photo-electricity conversion process and imaging mechanism and geometry parameter of X-ray flat-panel detector imaging system, the point spread function model of imaging system was obtained. The cylinder equivalented Gaussian function as the PSF of imaging system, so the complex deconvolution operation was replaced with algebraic equation. The workpiece radiography was gotten from the output image of the system. The model becomes the mathematical foundation that the output image estimates input image using linearity-invariant in practice testing. In the laboratory's DR system, based on the mathematical function, the sensitive model is obtained, so the input field intensity is effective recovery using output field intensity.
出处 《光学技术》 EI CAS CSCD 北大核心 2005年第4期630-632,共3页 Optical Technique
基金 国家自然科学基金资助项目(60172014)
关键词 非晶硅面阵探测器 线性时不变 点扩展函数 高斯函数 amorphous silicon tlat-panel detector linearity time-invariant point-spread function Gaussian function
  • 相关文献

参考文献5

  • 1邹异松等编著..光电成像原理[M].北京:北京理工大学出版社,1997:357.
  • 2路宏年,郑兆瑞编著..信号与测试系统[M].北京:国防工业出版社,1988:482.
  • 3Weisfield R L, Hartney M A, Street R A, et al. New amorphous-silicon image sensor for X-ray diagnostic medical imaging applications[J ]. Proceedings of SPIE, 1998, 3336 : 444-452. 被引量:1
  • 4Samei E. Image quality in two phosphor-based flat panel digital radiographic detectors[ J ]. Medical Physics, 2003, 30 (7) : 1747-1757. 被引量:1
  • 5Kenneth R.Leman C Digital image processing[M].北京:清华大学出版社.1998. 被引量:1

同被引文献25

  • 1雷平水,史伟民,徐菁,葛艳辉,邱永华,潘美军.多晶碘化汞膜的PVD法制备及其光电特性[J].半导体光电,2004,25(6):493-495. 被引量:6
  • 2王先华,乔延利,洪津.遥感图像恢复与遥感器MTF在轨检测技术[J].遥感技术与应用,2006,21(5):440-444. 被引量:8
  • 3Schieber M, Zuck A, Gilboa H, et al. Reviewing Polycrystalline Mercuric Iodide X-Ray Detectors[ J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (4) : 2385 - 2391. 被引量:1
  • 4Zentai G, Schieber M, Partain L, et al. Large area mercuric iodide and lead iodide X-ray detectors for medical and non-destructive industrial imaging[ J ]. Journal of Crystal Growth , 2005,275: e1327 - e1331. 被引量:1
  • 5Piechotka M, Kaldis E. Vaporization study of mercury iodides HgI2 and Hg212 [ J ]. J. Less- Common Metals, 1986,115: 315. 被引量:1
  • 6Shih Chen-Tsung, Huang Tang-Jung, Luo Ying-Zi, et al. Oriented polycrystalline HgI2 thick films grown by physical vapor deposition [ J ]. Journal of Crystal Growth, 2005,280: 442 - 447. 被引量:1
  • 7Dabrowski A J,Huth G C. [J]. IEEE Trans Nucl Sci, 1978, 1:208. 被引量:1
  • 8GE H Y, REN Q S, WANG B H, et al. Influence of pinhole size and fiber-optic imaging bundle on resolution in confocal endoscopic imaging system [ C ]. Proc. SPIE, 2005, 5633: 506-513. 被引量:1
  • 9NICHOLS C, BRYANT P, ALEXAY C. Advances in in- frared lens characterization: Measurement of MTF using common undersampled IR systems [ C ]. Proc. SPIE, 2007, 6543: 654314. 被引量:1
  • 10CAO X H, HUANG H K, LOU S L. A novel algorithm for measuring the MTF of a digital radiographic system with a CCD array detector[C]. Proc. SPIE, 2000, 3977: 580-589. 被引量:1