期刊文献+

同位素稀释火花源质谱法直接测定高纯氧化钆中的稀土杂质元素 被引量:1

Direct Determination of Trace Rare Earth Elements in High-purity Gadolinium Oxide by Isotope Dilution-Spark Source Mass Spectrometry
下载PDF
导出
摘要 本文采用同位素稀释火花源质谱法直接测定高纯氧化铁中 Nd、Sm、Eu、Dy、Ers个元素,再以该法测定的Nd和Er为内标,同时测定La、Ce,、Pr、Y和Tb、Ho、Tm、Lu 8个元素.方法的测定下限∑RE为8μg/g回收率为85%~114%.相对标准偏差为4%~21%. A method for the determination of trace Nd, Sm, Eu, Dy and Er in high-purity gadolinium oxide was developed by isotope dilution-spark source mass spectrometry. The trace elements, La, Ce, Pr, Y, Tb, Ho, Tm and Lu, are determined with respect to the internal standard Nd or Er determined by the method. The sum of the detection limits for 13 rare earth impurities is 8 μg/g. The recoveries are 85%-114%. The relative standard deviations are 4%-21%.
机构地区 [
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1995年第5期572-574,共3页 Chinese Journal of Analytical Chemistry
关键词 同位素稀释法 质谱 氧化钆 稀土杂质 Gadolinium, isotope dilution method, spark source mass spectrometry
  • 相关文献

参考文献4

  • 1周文证,核化工和稀土,1992年,1/2期,19页 被引量:1
  • 2游文海,分析试验室,1988年,7卷,4期,63页 被引量:1
  • 3李炳林,质谱学报,1986年,7卷,2期,30页 被引量:1
  • 4孟宪厚,质谱学报,1986年,7卷,2期,1页 被引量:1

同被引文献19

引证文献1

二级引证文献6