摘要
针对X射线荧光光谱仪的水冷系统内循环水压下降的问题,提出了在原冷却系统的泵前串接一个不锈钢泵的方法。经多年运行,效果好且费用低。
Maintenance and reconstruction of water cooling system for VF-320 X-ray fluorescence spectrometer were discussed in this paper. The problem of water pressure reduction in the system was solved by introducing a pump into the system and the result was satisfactory.
关键词
荧光光谱仪
水冷系统
维修
X辐射
X-ray spectrometer, water cooling system, maintenance and reconstruction, pump