期刊文献+

正常肾脏MSCT灌注成像的研究 被引量:16

The Study on MSCT Perfusion Imaging in Normal Kidney
下载PDF
导出
摘要 目的:探讨MSCT灌注成像在肾脏检查的初步临床应用。材料和方法:采用16排螺旋CT及灌注软件对32例双侧肾脏和12例单侧肾脏进行灌注扫描,对比剂为优维显(300mgIml)50ml,注射速度4mls。结果:32例双侧肾脏皮质或髓质的同一灌注指标无明显差异,但同侧肾脏皮质和髓质的同一灌注指标明显不同。一侧肾脏切除后,对侧肾脏的灌注指标变化明显。结论:MSCT灌注成像实现了肾脏血流的定量研究,可直观评价肾组织微循环的血液动力学变化。 Purpose: To evaluate the primary application of MSCT perfusion in kidney. Materials and Methods: Renal tissue perfusion was performed in 32 cases of bilateral kidneys and 12 cases of unilateral kidneys by applying MSCT and perfusion software with 50ml Ultravist (300mgI/ml)and 4ml/s injection flow. Results: Perfusion values in the cortex or medulla of bilateral kidneys of the 32 cases were not obviously different from each other respectively (P>0.05) but in the same kidneys, the perfusion values in the cortex showed great difference from those in the medulla (P< 0.05). After one side of the kidneys was removed the perfusion value for the other reserved one altered significantly. Conclusion: MSCT perfusion imaging provides quantitative information about renal blood flowing and effectively evaluates the hemodynamic change in renal tissue.
出处 《中国医学影像学杂志》 CSCD 2005年第4期275-278,共4页 Chinese Journal of Medical Imaging
关键词 MSCT 灌注成像 MSCT perfusion imaging kidney
  • 相关文献

参考文献7

  • 1娄明武 王继平 贾立中.CT灌注成像诊断超早期脑梗死的实验性研究[J].中华放射学杂志,2003,(37):129-129. 被引量:3
  • 2Beers BV, Leconte I, Materne R, et al. Hepatic Perfusion Parameters in Chronic Liver Disease: Dynamic CT measurements Correlated with Disease Severity.AJR,2001,176(3):667 被引量:1
  • 3Lee TY. Functional CT: physiological models. Trends in Biotechnology,2002,20(8):3 被引量:1
  • 4孙建男,么刚,李立军,郭启勇.肾脏CT灌注成像[J].中国医学影像技术,2004,20(8):1300-1302. 被引量:13
  • 5张景峰,王仁法,宋金梅,李勇刚,张菁,王敏华.兔VX2软组织肿瘤模型的建立与MSCT灌注成像研究[J].中国医学影像学杂志,2004,12(6):441-444. 被引量:7
  • 6Purdie TG, Henderson E, Lee TY. Function CT imaging of angiogenesis in rabbit VX2 soft-tissue tumor. Physics in Medicine and Biology, 2001,46(12):3161 被引量:1
  • 7Paul JF, Ugolini P, Sapoval M et al. Unilateral Renal Artery Stenosis: Perfusion Patterns with Electron-Beam Dynamic CT Preliminary Experience.Radiology,2001,221(1):261 被引量:1

二级参考文献36

  • 1周剑,高培毅.动态CT灌注成像临床应用中的质量控制[J].中国医学影像技术,2003,19(11):1576-1578. 被引量:6
  • 2[1]Nambu K, Takehara R, Terade T. A method of regional cerebral blood perfusion measurment using dynamic CT with an iodinated contrast medium[J]. Acta Neural Scand,1996,166(Suppl):28-31. 被引量:1
  • 3[2]Sinnatamby R, Watson C. Dynamic CT perfusion imaging of the transplanted liver[J]. Br J Radiol,1994,67(Suppl):134. 被引量:1
  • 4[3]Blomely MJ, Dawson P. Review article: the quantification of renal function with enhanced computed tomography[J]. Br J Radiol,1996,69(827):989-995. 被引量:1
  • 5[4]Miles KA. Measurement of tissue perfusion by dynamic computed tomography[J]. Br J Radiol,1991,64(761):409-411. 被引量:1
  • 6[5]Axel L. Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis[J]. Radiology,1980,137(3):679-686. 被引量:1
  • 7[6]Miles KA, Hayball MP, Dixon AK. Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging[J]. Br J Radiol,1995,68(809):471-475. 被引量:1
  • 8[7]Miles KA, Hayball M, Dixon AK. Colour perfusion imaging: a new application of computed tomography[J]. Lancet,1991,337(8742):643-645. 被引量:1
  • 9[8]Hamberg LM, Hunter GJ, Halpem EF, et al. Quantitative high-resolution measurement of cerebrovascular physiology with slip-ring CT[J]. AJNR,1996,17(4):639-650. 被引量:1
  • 10[9]Hindmarsh T. Elimination of water-solube contrast media from the subarachnoid space. Investigation with computed tomography[J]. Acta Radiol Suppl,1975,346(1):45-50. 被引量:1

共引文献18

同被引文献187

引证文献16

二级引证文献59

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部