采用仪器中子活化分析法测定了金属钇中Pr,Gd,Lu,Ho,Ce,La,Er等7种稀土元素的含量,计算了这些元素的检出限。标准参考物质的分析结果与推荐值基本相符。
Seven rare earth elements (REE), including La, Ce, Pr, Gd, Ho, Er, and Lu, in metal yttrium are determined by instrumental neutron activation analysis (INAA). The detection limit for each of these elements is estimated. The deterioration in dead time of the counting system caused by the bremsstralung from 90Y is minimized by absorption of its β- radiation with appropriate Perspex absorbent. The accuracy of the analytical method is verified by measurement of the reference material GBW-07313. The measured value for each element is in good accordance with its reference value.
出处
《核化学与放射化学》
EI
CAS
CSCD
北大核心
2005年第2期117-119,共3页
Journal of Nuclear and Radiochemistry
基金
中国工程物理研究院基金资助项目(42105)