摘要
作者介绍了自动洗片机定影液的配制方法及性能测定,6种胶片的定透时间及定影效果(密度差)。测定表明:自配定影液在温度30℃以上,冲洗全程150s(定影40s)以上,可满足胶片处理。2年来的实践证明,如此冲洗的胶片质量较好,能达到临床诊断要求。该药液配制方法简单,成本低廉,可替代商品套药在临床上的应用。
This article introduced the prescription and quality control of a fixer solution for au-tomatic processor. The time for fixing and the effectiveness density difference were measured for 6 kinds of films;The results showed that the optimal processing temperature is >30℃, the fotal pro-cessing time is l50s(40s for fixing).Based on 2 years of clinical experience with this fixer solution,the authors concluded that this flxer solution yields films of diagnostic quality, is easily made and of low cost,therefore is a good substitute for the current commercial fixer for automatic processor.
出处
《中华放射学杂志》
CAS
CSCD
北大核心
1995年第5期300-302,共3页
Chinese Journal of Radiology