摘要
玻璃钢电缆保护管直径d为(50~200)mm,管子壁厚t为(2~12)mm,变化范围很大.管子压扁线载荷和环向刚度变化很大.压扁弯曲强度随d/t的变化也有一定变化.本文对一批试验结果进行了统计及理论分析,得出统计方程及理论计算结果与试验符合,在使用保护管时很有实用价值.
The diameter of FRP cable protective pipes varies from 50 to 200 mm and the thickness of the pipe wall is from 2 to 12 mm. Then, their compression flat linear load and hoop rigidity also have a large scope. In this paper the statistics and theoretical analysis have been done and conforms to the test result, which gives much help for using protective pipes.
出处
《玻璃钢/复合材料》
CAS
CSCD
北大核心
2005年第4期12-15,共4页
Fiber Reinforced Plastics/Composites
关键词
玻璃钢
保护管
电缆
环向刚度
弯曲强度
FRP
protective pipe
cable
hoop rigidity
flexural strength