摘要
介绍了非晶合金铁芯变压器的性能,计算与比较了非晶合金变压器和S9变压器的综合节能及效益,并计算了50~800kVA的非晶合金变压器较同容量的S9变压器多投资的回收年限,提出了工程应用时的选择原则.
This article introduces the capability of amorphous core transformer(AMT), comparing the capability of economic benefit between AMT and S9 type transformer, calculating the number of years of reclaiming investment compared to the S9 type transformer in the same capacity. It calculates the cost of per load that AMT has realized in the whole operation period. Finally, the article suggests principles for choosing alternatives of the AMT in project application.
出处
《上海电力学院学报》
CAS
2005年第2期177-180,共4页
Journal of Shanghai University of Electric Power
关键词
非晶合金变压器
节能
选择原则
amorphous core transformer
enerny-saving
principles for choosing alternatives