摘要 目的探索在X线透视导航下使用Gamma钉治疗股骨转子间骨折的方法。同时,对依据导航特性设计的新型Gamma-3和以往使用的Gamma-AP内固定系统进行比较。方法66例股骨转子间骨折患者在导航下行Gamma钉植入(40例使用Gamma-AP,26例使用Gamma-3),由同一观察者记录各种术中数据。结果Gamma-3治疗组较Gamma-AP组手术时间短(平均32min),切口小(平均5cm),操作中X线照射时间短(7min),且拉力螺钉位置好(顶轴距17.9mm)。结论使用导航系统微创置入Gamma钉不仅进针方向精确,拉力螺钉位置好,切口小,而且还可以减少术者的X线暴露时间。由于Gamma-3依据导航特性设计,其效果优于Gamma-AP系统。 Objective To illustrate the application of fluoronavigation in Gamma nailing—a common surgical procedure in treatment of intertrochanteric fracture of femur and to compare the newly designed Gamma-3 system for navigation with the Gamma-AP system. Methods 66 patients with intertrochanteric fractures underwent Gamma nailing (40 Gamma-AP and 26 Gamma-3) under fluoronavigation guidance. An observer recorded the different intra-operative parameters. Results The Gamma-3 group showed superior results of shorter operation time (averaging 32 minutes), smaller surgical wound size (5cm), less X-ray requirement during procedure (7 times) and at the same time better lag screw position (Tip-Apex-Distance 17.9 mm). Conclusions Fluoronavigation can facilitate gamma nailing as a minimally invasive surgery because of its accurate guidance to nail insertion and lag screw positioning, a smaller surgical wound and minimized X-ray exposure suffered by operation theater staff. The Gamma-3 system has shown better results than the Gamma-AP system because of its navigation-specific design.
出处 《中华创伤骨科杂志》 CAS CSCD 2005年第7期646-648,共3页 Chinese Journal of Orthopaedic Trauma
关键词 X线透视导航 GAMMA钉 顶轴距 股骨转子间骨折 Fluoro-navigation Gamma nail Tip apex distance Intertrochanteric fracture
  • 相关文献

参考文献8

  • 1Cooper C, Campion G, Melton LJ 3rd. Hip fractures in the elderly: a world-wide projection. Osteoporos Int, 1992, 2: 285-289. 被引量:1
  • 2Leung KS, Chen CM, So WS, Sato K, Lai CH, Machaisavarariya B, Suntharalingam S. Multicenter trial of modified Gamma nail in East Asia. Clin Orthop, 1996, (323):146-154. 被引量:1
  • 3Leung KS, So WS, Shen WY, Hui PW. Gamma nails and dynamic hip screws for peritrochanteric fractures -a randomised prospective study in elderly patients. J Bone Joint Surg(Br), 1992, 74:345-351. 被引量:1
  • 4Grutzner PA, Suhm N. Computer aided long bone fracture treatment. Injury, 2004, 35(1 Suppl):57-64. 被引量:1
  • 5Joskowicz L, Milgrom C, Simkin A, Tockus L, Yaniv Z. FRACAS: a system for computer-aided image-guided long bone fracture surgery. Comput Aided Surg, 1998, 3:271-288. 被引量:1
  • 6Suhm N. Intraoperative accuracy evaluation of virtual fluoroscopy -a method for application in computer-assisted distal locking. Comput Aided Surg, 2001, 6:221-224. 被引量:1
  • 7Leung KS, Yung SHP, Tang N, Kwok KO, Yue HY. Clinical experience of Gamma nailing with fluoro-navigation. In: Langlotz F, Davis BL, Bauer A. Proceedings of 3rd International Annual Meeting of CAOS, 2003. 206-207. 被引量:1
  • 8Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fracture of the hip. J Bone Joint Surg(Am), 1995, 77:1058-1064. 被引量:1