摘要 【目的】评价镍钛机动器械Profile在磨牙根管治疗术一次法中的作用。【方法】将90颗牙髓炎、无症状死髓牙随机分配至3组,分别为Profile镍钛根管锉机动预备与侧压充填根管治疗一次完成组,K型不锈钢根管锉手动预备与侧压充填根管治疗一次完成组,K型不锈钢根管锉手动预备,侧压充填分次完成组,评价Profile机动预备与K型不锈钢根管锉手动预备完成一次性根管治疗术后反应、远期疗效,并与传统根管治疗多次法进行比较。【结果】在磨牙根管治疗术一次法中,Profile根管预备根管充填组术后反应明显少于K-file组,3组根管治疗远期疗效无显著性差异。【结论】镍钛机动器械在磨牙根管治疗术一次法中具有省时高效的优点,并能减少术后反应。 [Objective] To evaluate postoperative and long effect after root canal therapy performed in 1-appointment by Profile. [Methods] Eighty-two patients requiring root canal therapy on permanent molars were included in this study. Patients were randomly assigned to 3 groups. Both pulpitis and asymptomatic nonvital teeth were included. Teeth in group 1 (n = 30) were obturated at the first appointment by using laterally condensed gutta-percha after the canal prepared by Profile rotary files.Teeth in group2 (n = 30) were obturated at the first appointment by using laterally condensed gutta-percha after the canal prepared by K-file. Teeth in group3 (n = 30) were closed with calcium hydroxide paste and ZnO restoration and were obturated at a second appointment 7 days later. The postoperative and long effects were analyzed after the treatment. [Results] There was statistically difference in postoperative pain between patients treated in one appointment prepared by Profile and by K-file (P <0.05). There was no statistically significant difference between the three groups after one year. [Conclusion] The Profile rotary instrument could reduce stimulation and damage to the apical tissue during preparation and the root canal could be well shaped and compactly filled. Profile rotary instrument could reduce postoperative pain and improve the successful rate in 1-appointment root canal therapy.
出处 《中山大学学报(医学科学版)》 CAS CSCD 北大核心 2005年第4期473-475,共3页 Journal of Sun Yat-Sen University:Medical Sciences
  • 相关文献

参考文献10

  • 1史俊南.根管治疗术一次法.牙体牙髓牙周病杂志,2002,12(9):518-518. 被引量:16
  • 2邹韵秋,秦念红,许武玲.镍钛合金机用锉与超声波手用根管锉临床效果分析[J].中山医科大学学报,2001,22(5):393-394. 被引量:4
  • 3张延琳,吴惠华,曹颖光,李明,胡立桉.Profile机用根管器械治疗磨牙牙周牙髓联合病变的临床效果[J].中山医科大学学报,2002,23(3). 被引量:5
  • 4Bryant ST, Thompson SA, al-Omari MA. Shaping ability of profile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 1 [J]. Int Endod J, 1998; 31(4):275-81. 被引量:1
  • 5Ahlquist M, Henningsson O, Hultenby K, et al. The effectiveness of manual and rotary techniques in the cleaning of root canals:a scanning eletron microscopy study[J]. Int Endod J, 2001, 34(7):533-7. 被引量:1
  • 6Reddy SA, Hicks ML. Apical extrusion of debris using two hand and rotary instrumentation techniques [J]. J Endod, 1998, 24(3):180-3. 被引量:1
  • 7Podbielski A, Spahr A, Haller B.Additive antimicrobial activity of calcium hydroxide and chlorhexidine on common endodontic bacterial pathogens [J]. J Endod,2003,29(5):340-5. 被引量:1
  • 8Haenni S, Schmidlin PR, Mueller B, et al. Chemical and antimicrobial properties of calcium hydroxide mixed with irrigating solutions [J]. Int Endod J, 2003,36(2):100-5. 被引量:1
  • 9DiRenzo A, Gresla T, Johnson BR, et al. Postoperative pain after 1- and 2-visit root canal therapy [J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2002,93(5):605-10. 被引量:1
  • 10Parashos P, Messer HH. Questionnaire survey on the use of rotary nickel-titanium endodontic instruments by Australian dentists [J]. Int Endod J, 2004,37(4):249-59. 被引量:1

二级参考文献9

共引文献20

同被引文献6

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部