期刊文献+

假肢接受腔阳模数控加工刀具的运动轨迹规划

Tool path planning of CNC machine tool for prosthetics socket
下载PDF
导出
摘要 应用表面建模方法,建立了假肢接受腔的三维数学模型.针对假肢接受腔的独特外形特征,研制了加工假肢接受腔阳模的三轴联动数控机床,该机床控制系统采用开环系统,可以运行CAD/CAM软件.对加工假肢接受腔阳模的刀具进行了运动轨迹规划,推导出了切削点的计算公式.根据三维刀具半径补偿原理,确定了刀具的刀位点运动轨迹.经过临床实例加工表明:该数控机床和刀具运动轨迹规划算法完全满足实际应用要求.
出处 《高技术通讯》 CAS CSCD 北大核心 2005年第6期38-41,共4页 Chinese High Technology Letters
基金 国家高技术研究发展计划(863计划)
  • 相关文献

参考文献6

  • 1He P, Xue K F, Chen Q, et al. A PC-based ultrasonic data acquisition system for computer-aided prosthetic socket design. IEEE Transaction Rehabilitation Engineering, 1996, (4):114. 被引量:1
  • 2Arthru F T M, Zhang Ming, David A B, et al. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: A review. Journal of Rehabilitation Research and Development, 2001, 38(2): 161. 被引量:1
  • 3Ng P, Lee P S V, et al. Prosthetic sockets fabrication using rapid prototyping technology. Rapid Prototyping Journal, 2002, 8(1): 53. 被引量:1
  • 4Zhang M, Mak A F T, Roberts V C. Finite element modeling of a residual lower-limb in a prosthetic socket: a survey of the development of the first decade. Medical Engineering and Physics, 1998: 360. 被引量:1
  • 5郑淑贤,赵万华,卢秉恒.假肢接受腔数字化技术研究进展[J].北京生物医学工程,2004,23(3):232-235. 被引量:8
  • 6刘德福,陈峰.计算机数控系统三维刀具半径补偿研究[J].组合机床与自动化加工技术,2001(8):9-11. 被引量:14

二级参考文献18

  • 1林浩.数控加工程序编制[M].北京:航空工业出版社,1993.. 被引量:1
  • 2[2]Dudley SC. Presentation highlights: Computer-Aided Design and Manufacture (CAD-CAM). Journal of Rehabilitation Research and Development, 2002, 39 (3): 15- 16 被引量:1
  • 3[3]Zheng YP, Arthur FTM, Aaron KLL. State-of-the-art methods for geometric and biomechanical assessments of residual limbs: A review. Journal of Rehabilitation Research and Development, 2001: 487- 504 被引量:1
  • 4[5]He P, Xue KF, Chen Q, et al. A PC-based ultrasonic data acquisition system for computer-aided prosthetic socket design. IEEE Transaction Rehabilitation Engineering, 1996, 4: 114- 119 被引量:1
  • 5[6]Zhang M, Mak AFT, Roberts VC. Finite element modeling of a residual lower-limb in a prosthetic socket: a survey of the development of the first decade. Medical Engineering and Physics, 1998: 360- 373 被引量:1
  • 6[7]Zachariah SG, Sanders JE. Interface mechanics in lower-limb external prosthetics: a review of finite element models. IEEE Transaction Rehabilitation Engineering, 1996, 4 (4): 288-302 被引量:1
  • 7[8]Liu GHW, Mak AFT, Lee SY. Biomechanical assessment of below-knee residual limb tissue. Journal of Rehabilitation Research and Development, 1994:188 - 198 被引量:1
  • 8[9]Zheng YP, Mak AFT. An ultrasound indentation system for biomechanical properties assessment of soft tissues in-vivo. IEEE Transaction Rehabilitation Engineering, 1996, 43 (9): 912-918 被引量:1
  • 9[10]Zhang M, Turner-Smith AR, Roberts VC, et al. Frictional action at residual limb/prosthetic socket interface. Medical Engineering and Physics, 1996, 18 (3): 207- 214 被引量:1
  • 10[11]Zhang M, Mak AFT, A finite element analysis of the load transfer between a residual limb and its prosthetic socket-Roles of interfacial friction and distal-end boundary conditions. IEEE Transaction Rehabilitation Engineering [C], 1996, 4 (4): 337 - 346 被引量:1

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部