摘要 目的通过CT法及裸骨投照测量法(以下简称“裸骨法”)测量股骨扭转角的比较,探讨CT测量扭转角的可靠性。方法分别采用CT法及裸骨法测量80个股骨标本股骨扭转角,对测定值进行统计学分析,并作左右两侧比较。结果采用CT法测量的扭转角为11.04°±8.24°(-6.1°~34.0°);裸骨法测量的扭转角为11.27°±8.01°(-5.5°~34.2°)。两者间的扭转角度相差0.23°±1.64°(-4.4°~3.4°),差异无显著性意义(P>0.05,配对样本t检验)。左右两侧对比,差异无显著性意义(P>0.05,独立样本t检验)。结论CT测量法是临床测定股骨扭转角确实可靠的方法,临床上健侧的扭转角可作为参考依据。 Objective Compared with CT scan method and “bare-bone method” of measuring femoral torsion angle, to study the reliability of measuring torsion angle by means of CT method. Methods Torsion angles were measured with CT method and a new photogrammery of digital camera respectively in 80 femoral specimens. Compared of the values in both left and right sides. All the values were analyzed with SSPS. Results Mean value of torsion angle with CT method was 11.04°(-6.1°~34.0°, s=8.24°) and 11.27°(-5.5°~34.2°, s=8.01°) with digital photogrammery. There was no difference of statistical significance between them(P>0.05, paired samples t test). Comparison of the values in both left and right sides was without difference of statistical significance(P>0.05, Independent-samples t test). Conclusion CT method is an accurate and reliable method to measure the femoral torsion angle. Torsion angle in normal side is regard to a reference value in clinic.
出处 《实用骨科杂志》 2005年第3期225-227,共3页 Journal of Practical Orthopaedics
关键词 股骨 扭转 体层摄影术 X线计算机 摄影测量法 femur torsion tomography X-ray computed photogrammery
  • 相关文献

参考文献8

  • 1Banchong M,Kriskrai S,Trongtum T,et al.Morphological study of the proximal femur:a new method of geometrical assessment using 3-dimensional reverse engineering[J].Med Eng Phys,2002,24:617-622. 被引量:1
  • 2Hermann KL,Egund N.Measuring anteversion in the femoral neck from routine radiographs[J].Acta Radiol,1998,39:410-415. 被引量:1
  • 3Peterson HA,Klassen RA,Mcleod RA,et al.The use of computerised tomography in dislocation of the hip and femoral neck anteversion in children[J].J Bone Joint Surg(Br),1981,63:198-208. 被引量:1
  • 4裘法祖.外科学[M](第4版)[M].北京:人民卫生出版社,1999.437-438. 被引量:6
  • 5纪盛章,崔存成,陈胜利,赵庆,程喜定,李超英,王熙荣,李宝琪,杨建平.股骨颈前倾角三维CT测量方法[J].中华骨科杂志,2001,21(3):187-188. 被引量:23
  • 6Fabeck L,Parewyck S,Rooze M,et al.Gemometrical analysis of the femoral neck torsion[J].Cells Tissues Organs,2000,167:68-72. 被引量:1
  • 7孔晓川,陆应隆,周建,安立琨,刘军,刘苏英.股骨颈旋转角的CT研究[J].中国矫形外科杂志,2002,9(11):1106-1107. 被引量:4
  • 8张怀瑫,郑靖中,杨玉田.国人股骨颈干角及扭转角的测量统计[J].解剖学报,1982(3):262-270. 被引量:16

二级参考文献4

  • 1裘法祖.外科学,第4版[M].北京:人民卫生出版社,1998.714. 被引量:9
  • 2郭世绂.临床骨科解剖学[M].天津:天津科学技术出版社,1992.156. 被引量:32
  • 3陆应隆 孔晓川.髋置换术中头假体旋转角[J].美国中华骨科杂志,1999,3:359-360. 被引量:1
  • 4屈辉,中华放射学杂志,1995年,30卷,672页 被引量:1