期刊文献+

Cerec 2型机摄像头的口外控制装置对CAD/CAM全瓷底层冠适合性的影响 被引量:11

Effect of Camera Control Devices of Cerec 2 on the Fit of CAD/CAM All-ceramic Copyings of Posterior Tooth
下载PDF
导出
摘要 目的了解Cerec2型机摄像头的口外控制装置对CAD CAM全瓷底层冠适合性的影响。方法采用口外控制装置的摄像头与未使用控制装置的摄像头对照,分别采集光学印模形成数字化模型,加工VitaMKⅡ及自行研制的多孔氧化铝瓷,制作24个全瓷底层冠,经包埋、切开后,使用扫描电镜和计算机图像分析仪测量底层冠内部和边缘间隙,比较其适合性差异。结果使用控制装置组同未使用控制装置组相比:颊侧颈部间隙有明显差异(P<0.05),轴壁间隙除舌侧外,在近中、远中、颊侧均有显著性差异(P<0.05),在远中顶壁、颊侧顶壁、舌侧顶壁均有显著性差异(P<0.05);VitaMKⅡ底层冠与多孔氧化铝底层冠在边缘间隙及内部间隙均无显著性差异(P>0.05)。结论使用控制装置的Cerec2型机有效地减小了人为操作造成底层冠内部间隙的误差,为底层冠的粘接剂提供均匀的内部空间;自行研制的多孔氧化铝瓷经机加工后,其适合性与VitaMKⅡ相似,均达到了临床的要求。 Objective To investigate the effect of camera control devices of Cerec 2 on the fit of CAD/CAM all_ceramic copyings of posterior tooth. Methods 24 all_ceramic copyings were made by Cerec 2 with camera control devices and that without camera control devices. Copyings were embed and sectioned, then SEM and image analyzer was used to measure the space between the copyings and dies at the marginal opening, the axial wall, and the occlusal adaptation at the measurement locations. Results ①The marginal fit at buccal space of copyings with camera control devices group was smaller than that without camera control devices group(P<0.05). ②The internal fit of of copyings had statistically significant difference at mesio_axial,disto_axial,bucco_axial,bucco_occlusal,linguo_occlusal and disto_occlusal space between camera control device group and without camera control devices group(P<0.05). ③There was no statistical difference on the marginal fit and internal fit of copyings between Vita MK Ⅱ and porous alumina oxide(P<0.05). Conclusion The Cerec 2 with camera control devices reduced effectively the inaccuracy of inner space of copyings which contributed from the technical errors of the operator, and provided well_proportioned space for adhesive. Both the fit of copyings made of Vita MK Ⅱand porous alumina oxide satisfied the clinical demand.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 2005年第3期247-250,共4页 West China Journal of Stomatology
基金 国家自然科学基金资助项目(39970799)
关键词 计算机辅助设计/计算机辅助制作 全瓷底层冠 适合性 computer aided design/computer aided manufacture all_ceramic copying fit
  • 相关文献

参考文献6

  • 1Bindle A, Mormann W. Klinische and technische aspekte der CEREC-in-Ceram-krone[J]. Quintessenze, 1996,6:775-792. 被引量:1
  • 2Bindle A, Mormann W. Chairside-computer -Kronen-Verfahrenszeit and klinische qualitat[J]. Acta Med Dent Helv, 1997,2(12):293-300. 被引量:1
  • 3Persson M, Andersson M, Bergman B. The accuracy of a high-precision digitizer for CAD/CAM of crowns[J]. J Prosthet Dent, 1995,74(3):223-229. 被引量:1
  • 4Wiedhahn K. The optical Cerec impression electronic model producting[J]. Int J Comput Dent, 1998,1(1): 41-54. 被引量:1
  • 5Mclean JW, Frauhofer JAV. The estimation of cement film thickness by an in vivo technique[J] . Br Dent J,1971,131(3):107-111. 被引量:1
  • 6骆小平,赵云凤,田杰模,巢永烈,张世新,张云龙.氧化铝玻璃复合体强度及断裂韧性的研究[J].上海生物医学工程,1998,19(1):10-12. 被引量:2