摘要
通过测试,得出了在单一风机、一拖二风机及夹套式三种不同送风方式下的90 m3微型冷库内离地面1 .5 m处的温度场分布。结果表明,夹套式送风方式的微型预冷库具有最好的温度场分布。根据实验结果建立了果蔬预冷时温度降速率、压力降速率及温度变化率的相关耦合式。
By experimental measurement of air distribution with different air supplying modes, including single inlet, double inlets and jacket supplying modes, in mini-cold storage, the temperature distribution at 1.5 m in 90 m 3 mini-cold storage were obtained. Results show that the temperature distribution in jacket mini-cold storage is the most uniform. The optimum pre-cooling air velocity on a certain stacked type was proposed based on the coupling formula of the temperature drop rate, the pressure drop rate and the change rate of the temperature of stored products.
出处
《热科学与技术》
CAS
CSCD
2005年第2期118-122,共5页
Journal of Thermal Science and Technology