期刊文献+

楼宇中央空调计算机监控系统的设计及实施 被引量:3

Design and Implementation of Central Air-conditioner Computer Monitored Control System
下载PDF
导出
摘要 针对日益复杂的楼宇中央空调的监控要求,分析了楼宇中央空调控制系统的干扰因素,并重点阐述了空调湿度控制系统的特点。实验表明空调湿度控制系统具有一定的时变时滞特性,控制策略使用了鲁棒数字PII。该策略的主要控制思想是:"小"比例和积分控制实现时变时滞的鲁棒调节控制、修正积分控制抑制定值负载干扰。监控部分采用小型集散控制系统,并详细介绍了该监控系统的组成方案及仪表选型,最后简述了该监控方案的运行效果和节能效果。 The disturbing factors of central air-conditioner control system in the office building are studied for the increasing complicated requirements of monitored control central air-conditioner. The characteristics of air-conditioner humidity monitoring system are emphasized. The experiments show that the air-conditioner humidity monitor system has the properties of time varying and time delay. Robust digital PII is applied in monitor strategy. The'little' proportion + time varying and time delay robust adjusting monitor is controlled by integral, and the fixed value loading interference is restrained by adjusting integral monitor. Mini-typed distributed control system is adopted in monitor section. Composing scheme of this monitor system and selecting meters are introduced in detailed. The function and saving-energy effects of this scheme are also summarized.
出处 《控制工程》 CSCD 2005年第3期260-262,共3页 Control Engineering of China
基金 国家自然科学基金重点资助项目(50235040)
  • 相关文献

参考文献4

  • 1杨绍胤主编..智能建筑实用技术[M].北京:机械工业出版社,2002:590.
  • 2杨志等编著..建筑智能化系统及工程应用[M].北京:化学工业出版社,2002:280.
  • 3赵乱成..智能建筑设备自动化技术[M],2002.
  • 4罗国杰..智能建筑系统工程[M],2002:303.