摘要
介绍了不同于常规的绝缘子在线监测报警方式,该方法运用了模糊集合理论,首先提出了基于泄漏电流和环境湿度的模糊报警方式,然后提出了基于泄漏电流,环境湿度和温度的三输入的改进的模糊报警方式.
The article introduces a method for insulator on-line monitoring,which differs from the common ones. The method applies fuzzy theory. First, the article introduces the fuzzy alame model which is based on leakage current and air humid. Then, another fuzzy alarm model which is improved based on leakage current,air humid and temperature are introduced.
出处
《新疆大学学报(自然科学版)》
CAS
2005年第2期219-223,共5页
Journal of Xinjiang University(Natural Science Edition)
关键词
泄漏电流
湿度
温度
模糊报警
leakage current
humid
temperature
fuzzy alarm