摘要
介绍一起大电流变压器低压套管过热的故障, 通过电气试验, 并结合该变压器的历史情况, 对过热故障的发展过程进行了分析, 就变压器低压套管连接结构存在的问题, 提出了改进意见。
An overheat fault on the LV bushing of a heavy-current transformer is described in this paper.Based on the electric test and the historical data of the transformer,this paper analyses the development course of the bushing overheat.In light of the problems existing in the joining of the transformer LV bushing,improving measures are also presented to prevent similar faults.
出处
《广东电力》
2005年第3期60-63,共4页
Guangdong Electric Power
关键词
变压器
套管
过热
分析
transformer
bushing
overheat
analysis