摘要
本文在严格的非定常传热理论基础上,应用理论和工程相结合的方法,建立了适用的物理和数学模型,给出了合理的定解条件。用FORTRAN语言编制了计算机程序,并在VAX机上进行了计算。典型计算结果表明,郑州地区冬季不采暖,室温可达14℃。
Based on the unstable heat transmission theory and its application to construction,this paper sets up a praticticable physical and mathematical model and presents reasonableconditions for solution. Computer programs are designed with the FORTRAN languageand calculations are made on the VAX 11 /785 computer.The results show that a roomtemperature of about 14℃ can be obtained without heating in Zhengzhou.
关键词
建筑
节能
数学模型
计算方法
energy-saving building,mathematical model,calculation