摘要
分析了医院洁净空调存在的问题,讨论了配有负压灭菌局部排风单元的独立新风系统在医院洁净空调的应用。经过对某房间的粒子浓度进行实测,效果良好。
Problems existing in clean air conditioning for hospital are analyzed, and the application of dedicated outdoor air system fitted with local air exhaust unit with negative pressure sterilization in the clean air conditioning for hospital is discussed. The measured result of particle concentration in a certain room shows that this system has a better effect.
出处
《煤气与热力》
2005年第3期33-35,共3页
Gas & Heat
关键词
洁净空调
独立新风系统
负压灭菌局部排风单元
clean air conditioning
dedicated outdoor air system
local air exhaust unit with negative pressure sterilization